Triboelectric Nanogenerator (TENG)

Sampling ultra precious materials is a balance between acquiring enough sample to perform the required analysis, but also minimizing the volume of material used either during invasive procedures (e.g. biopsies) or when abundant sample is not available. While mass spectrometry (MS) techniques are sensitive for the low-sample quantities obtained, the destructive nature of the technique can make it undesirable in cases where repeated sampling is needed. Additionally the targeted analysis of proteins can be challenging by MS alone without front-end separation that is often sample-expensive and may not be amenable for the limited sample extracted. By using Triboelectric Nanogenerators (TENG) hyphenated with ion mobility-mass spectrometry (IM-MS) techniques we aim to both minimize the amount of sample needed for a traditional MS method as well as increase the information content obtained from ultra precious samples.

What are triboelectric nanogenerators?

Triboelectric Nanogenerator (TENG) electrospray ionization sources, first described as mechanical generators for microelectronics1, have been shown to have excellent MS applications providing sensitivity and reproducible measurements for several molecular classes2,3. By taking two triboelectric materials and either putting them in contact, or sliding them, with one another mechanical energy can be converted to electricity, and this electric current can be redirected using a circuit to an ion source. Recently, these devices have also been shown to be able to generate protein ions that would be consistent with native structures4, and with precise tuning to be capable of synchronous data acquisition with time dispersive instruments to maximize sample limited analytes5.

Why TENG?

TENG is advantageous because they are simple devices that works by placing two triboelectric materials into contact to generate triboelectricity that can be used to power the ion source that generates ions for an MS instrument. These devices have also been shown to be capable of generating sufficient signal with picoliter volume quantities and sub-micromolar concentrations of sample2,5. When combined with other state-of-the-art instrumentation and methodologies (e.g top-down, native, ion mobility, etc.), TENG is potentially transformative for the characterization of ultra-precious materials by minimizing the amount of material extracted and provide structure and stability information content currently unobtainable with existing technologies.

(A) Sub-microliter sample volume injected in emitter. (B) Emitter is housed in front of mass spectrometer sampling cone. (C) Pulsed ion signal can modulated to match time-dispersive instruments maximizing duty cycle.

Further Reading

(1)      Wang, Z. L. Triboelectric Nanogenerators as New Energy Technology and Self-Powered Sensors – Principles, Problems and Perspectives. Faraday Discuss. 2014, 176 (11), 447–458.

(2)      Li, A.; Zi, Y.; Guo, H.; Wang, Z. L.; Fernández, F. M. Triboelectric Nanogenerators for Sensitive Nano-Coulomb Molecular Mass Spectrometry. Nat. Nanotechnol. 2017, 12 (5), 481–487.

(3)      Bernier, M. C.; Li, A.; Winalski, L.; Zi, Y.; Li, Y.; Caillet, C.; Newton, P.; Wang, Z. L.; Fernández, F. M. Triboelectric Nanogenerator (TENG) Mass Spectrometry of Falsified Antimalarials. Rapid Commun. Mass Spectrom. 2018, 32 (18), 1585–1590.

(4)      Bouza, M.; Li, Y.; Wu, C.; Guo, H.; Wang, Z. L.; Fernández, F. M. Large-Area Triboelectric Nanogenerator Mass Spectrometry: Expanded Coverage, Double-Bond Pinpointing, and Supercharging. J. Am. Soc. Mass Spectrom. 2020, 31 (3), 727–734.

(5)      Li, Y.; Bouza, M.; Wu, C.; Guo, H.; Huang, D.; Doron, G.; Temenoff, J. S.; Stecenko, A. A.; Wang, Z. L.; Fernández, F. M. Sub-Nanoliter Metabolomics via Mass Spectrometry to Characterize Volume-Limited Samples. Nat. Commun. 2020, 11 (1), 1–16.

Meta

  • Log in
  • Entries RSS
  • Comments RSS
  • Sites@GeorgiaTech

CONTACT

Fernández group
Georgia Institute of Technology
School of Chemistry and Biochemistry
ES&T L1244
901 Atlantic Drive Atlanta, GA 30332

Phone: (404) 385-4432
Fax: (404) 894-7452

Archives

Copyright © 2025 · Agency Pro on Genesis Framework · WordPress · Log in